Double walled steel tube,low carbon steel with PVF coated,3/16" O.D.with 0.71mm thickness,with flare tube fittings for trucks.
Double walled steel tube:Low carbon steel;PVF coated;3/16″ O.D.;0.71mm thickness;With flare tube fittings;For trucks.
Features:
Available Covering Finishes of Double Walled Steel Tube:White zinc plated,Yellow zinc plated,Dark green plated,PVF..
Available Package Type of Double Walled Steel Tube :In roll,In bulk roll,In pancake,In straight or special request..
Our Copper-Brazed Steel Tubing confirm to the ASTM A254-97 Standard Specificaion.It can be used for fuel lines,brake lines,oil lines of Automotive uses,cooling units of refrigeration uses and stove industries.ect.It made by rolling steel trip into the form of tubing and subsequently copper brazing in a reducing atmosphere.After a various of analysis,like heat analysis and product analysis,and through tension tensile strength,flattening,expansion,bending and pressure proof test to ensure the quality.
Two types of copper-brazed steel tubing for choice:Single Strip Type or Double Strip Type.
Dimensions and Tolerances | |||||
Nominal Tubing OD | Outside Diameter | Wall Thickness | |||
inch | mm | Basic mm | Tolerance± | Basic mm | Tolerance± |
3/16 | 4.76 | 4.78 | 0.08 | 0.71 | 0.08 |
1/4 | 6.35 | 6.35 | 0.08 | 0.71 | 0.08 |
5/16 | 8 | 7.92 | 0.08 | 0.71 | 0.08 |
3/8 | 9.52 | 9.53 | 0.08 | 0.71 | 0.08 |
1/2 | 12.7 | 12.7 | 0.1 | 0.89 | 0.09 |
Specification and Test
Test Item | Technical Standard | Test result | |||||
Mechanical Property | Tensile Strength290Mpa | 296Mpa | |||||
Yield Strength 180Mpa | 185Mpa | ||||||
Elongation20% | 30% | ||||||
Wall Thickness | 0.70+-0.1mm | 0.71mm | |||||
Flaring Test | Flaring25% | 30% | |||||
Bending Test | Bend 180°C in a Radius Three Times of the Pipe Diameter | No Crafk or Peeling After Flaring | |||||
Flattening Test | No Crack After Flattening | No Crack | |||||
Pressure Test | No Leakage when Charged with 34.3Mpa Nitrogen Gas for 1min | No Leakage | |||||
Thickness per Surface Treatment of Galvanize(μm) | 9μm | ||||||
Thickness per Inner Treatment of Copper-Plating | 3μm |